During the anti-recycling period of starting-up the compressor, each time interval for re-starting the compressor is recommended to follow the above illustration.
Please, help with definition, what type of period it is.
Please, help with definition, what type of period it is.
Responses
4 | anti-recycling period | Jennifer Levey |
Responses
4 hrs
Selected
anti-recycling period
The compressor is probably equipped with some kind of fault detection system (over-pressure, motor overload, etc.) which will shut down the compressor if it detects such a fault.
However, such 'faults' may occur for a very short period of time while the compressor is in normal 'start-up' mode' (in which the machine is more stressed than during normal operation), and the 'anti-recycling' system will prevent these ocurrences being interpreted as 'faults requiring shut-down' during this start-up period (i.e. will over-ride the fault detector). Without such as system the compressor would probably never start properly at all....
The 'anti-recycling period' will be the period of time during which this 'fault override' system is active.
--------------------------------------------------
Note added at 5 hrs (2007-12-12 00:39:57 GMT)
--------------------------------------------------
With his note (below) I think asker has answered his own question ... The compressor must not (instruction to human operator) or cannot (built-in protection device) be restarted more than X times per hour.
But it's *very different* to my answer ... since according to asker it's a simple 'restarts/hour' limit, unrelated to short-term pseudo-fault conditions during each start-up.
--------------------------------------------------
Note added at 5 hrs (2007-12-12 00:44:42 GMT) Post-grading
--------------------------------------------------
I agree, the English is not native (and I say that as a native English-speaker myself)). But clear enough, I think ...
However, such 'faults' may occur for a very short period of time while the compressor is in normal 'start-up' mode' (in which the machine is more stressed than during normal operation), and the 'anti-recycling' system will prevent these ocurrences being interpreted as 'faults requiring shut-down' during this start-up period (i.e. will over-ride the fault detector). Without such as system the compressor would probably never start properly at all....
The 'anti-recycling period' will be the period of time during which this 'fault override' system is active.
--------------------------------------------------
Note added at 5 hrs (2007-12-12 00:39:57 GMT)
--------------------------------------------------
With his note (below) I think asker has answered his own question ... The compressor must not (instruction to human operator) or cannot (built-in protection device) be restarted more than X times per hour.
But it's *very different* to my answer ... since according to asker it's a simple 'restarts/hour' limit, unrelated to short-term pseudo-fault conditions during each start-up.
--------------------------------------------------
Note added at 5 hrs (2007-12-12 00:44:42 GMT) Post-grading
--------------------------------------------------
I agree, the English is not native (and I say that as a native English-speaker myself)). But clear enough, I think ...
Note from asker:
I think you are close. Now, I think it is a period when it is prohibited to start up the compressor. The paragraph title is "Compressor restart frequency" and then The restart counts for the models of XX10 ~ XX16 are recommended below 6 times in one hour, i.e. the startup count of the motor is not allowed to be over 6 times in one hour; as to another models of XX17 ~ XX21 are recommended not to be over 4 times in one hour, and models of XX22~XX24 are recommended not to be over 3 times in one hour. |
I feel, English is not perfect here, the explanation looks chunky. |
This is what we normally have to deal with in Russia - to translate second grade English. |
4 KudoZ points awarded for this answer.
Comment: "Sure, but it is you who gave me an idea. Thank you very much! "
Something went wrong...